Neuropsychological assessment of visual selective attention and processing capacity with head-mounted displays.

Foerster RM, Poth CH, Behler C, Botsch M, Schneider WX (2019)
Neuropsychology 33(3): 309-318.

Zeitschriftenaufsatz | Veröffentlicht | Englisch
 
Download
OA 116.64 MB
Abstract / Bemerkung
Objective: Neuropsychological patients often suffer from impairments in visual selective attention and processing capacity components. Their assessment demands a high standardization of testing conditions, which is difficult to achieve across institutions. Head-mounted displays (HMDs) provide a solution. These virtual reality devices cover the entire visual field in a shielded way and thus keep visual stimulation constant. For neuropsychological assessment with HMDs, sufficient reliability is required. We have previously demonstrated that an early developer version of an HMD can be used to reliably measure components of visual processing capacity. However, it is unclear whether this also holds for the assessment of components of visual selective attention. Moreover, it has yet to be established whether now commercially available HMDs are capable of reliable neuropsychological assessment. Method: We assessed the test-retest reliabilities of several components of visual selective attention and processing capacity of healthy subjects with the commercially available HTC Vive. Using an assessment procedure (combiTVA) derived from the theory of visual attention (Bundesen, 1990), we measured attentional selectivity, lateral bias, processing speed, visual working memory capacity, and the threshold of conscious perception. We compared the reliabilities of these components measured with the HTC Vive with those of a cathode ray tube (CRT)-screen, the gold-standard of visual presentation in the laboratory. Results: Both devices provided comparable reliabilities. Conclusions: Thus, HMDs fulfill the requirement to replace standard screens. With their inherent visual standardization and portability, they offer unprecedented opportunities for neuropsychological assessment, such as computerized bedside testing and comparisons of test values across institutions.
Stichworte
virtual reality; head-mounted display; visual attention; visual capacity; neuropsychological diagnostics; test-retest reliability
Erscheinungsjahr
2019
Zeitschriftentitel
Neuropsychology
Band
33
Ausgabe
3
Seite(n)
309-318
ISSN
0894-4105
eISSN
1931-1559
Page URI
https://pub.uni-bielefeld.de/record/2933354

Zitieren

Foerster RM, Poth CH, Behler C, Botsch M, Schneider WX. Neuropsychological assessment of visual selective attention and processing capacity with head-mounted displays. Neuropsychology. 2019;33(3):309-318.
Foerster, R. M., Poth, C. H., Behler, C., Botsch, M., & Schneider, W. X. (2019). Neuropsychological assessment of visual selective attention and processing capacity with head-mounted displays. Neuropsychology, 33(3), 309-318. https://doi.org/10.1037/neu0000517
Foerster, Rebecca M., Poth, Christian H., Behler, Christian, Botsch, Mario, and Schneider, Werner X. 2019. “Neuropsychological assessment of visual selective attention and processing capacity with head-mounted displays.”. Neuropsychology 33 (3): 309-318.
Foerster, R. M., Poth, C. H., Behler, C., Botsch, M., and Schneider, W. X. (2019). Neuropsychological assessment of visual selective attention and processing capacity with head-mounted displays. Neuropsychology 33, 309-318.
Foerster, R.M., et al., 2019. Neuropsychological assessment of visual selective attention and processing capacity with head-mounted displays. Neuropsychology, 33(3), p 309-318.
R.M. Foerster, et al., “Neuropsychological assessment of visual selective attention and processing capacity with head-mounted displays.”, Neuropsychology, vol. 33, 2019, pp. 309-318.
Foerster, R.M., Poth, C.H., Behler, C., Botsch, M., Schneider, W.X.: Neuropsychological assessment of visual selective attention and processing capacity with head-mounted displays. Neuropsychology. 33, 309-318 (2019).
Foerster, Rebecca M., Poth, Christian H., Behler, Christian, Botsch, Mario, and Schneider, Werner X. “Neuropsychological assessment of visual selective attention and processing capacity with head-mounted displays.”. Neuropsychology 33.3 (2019): 309-318.
Alle Dateien verfügbar unter der/den folgenden Lizenz(en):
Copyright Statement:
Dieses Objekt ist durch das Urheberrecht und/oder verwandte Schutzrechte geschützt. [...]
Volltext(e)
Name
Access Level
OA Open Access
Zuletzt Hochgeladen
2019-09-25T06:51:28Z
MD5 Prüfsumme
2468a841077be015f6024ed2bec131bb


Material in PUB:
Frühere Version
Virtual reality test of visual performance: Processing speed and working memory
Behler C, Poth CH, Foerster RM, Schneider WX, Botsch M (2016)
Bielefeld University.
In sonstiger Relation
Virtual reality test of visual performance: Selective attention, processing speed, and working memory
Behler C, Poth CH, Foerster RM, Schneider WX, Botsch M (2018)
Bielefeld University.
Frühere Version
Using the virtual reality device Oculus Rift for neuropsychological assessment of visual processing capabilities
Foerster RM, Poth CH, Behler C, Botsch M, Schneider WX (2016)
Scientific Reports 6(1): 37016.
Export

Markieren/ Markierung löschen
Markierte Publikationen

Open Data PUB

Web of Science

Dieser Datensatz im Web of Science®
Quellen

PMID: 30652888
PubMed | Europe PMC

Suchen in

Google Scholar