Diagnosing asthma in general practice with portable exhaled nitric oxide measurement – results of a prospective diagnostic study

Schneider, Antonius ; Tilemann, Lisa ; Schermer, Tjard ; Gindner, Lena ; Laux, Gunter ; Szecsenyi, Joachim ; Meyer, Franz Joachim

In: Respiratory Research, 10 (2009), Nr. 15. pp. 1-11. ISSN 1465-993X

[thumbnail of 12931_2008_Article_729.pdf]
Preview
PDF, English
Download (1MB) | Lizenz: Creative Commons LizenzvertragDiagnosing asthma in general practice with portable exhaled nitric oxide measurement – results of a prospective diagnostic study by Schneider, Antonius ; Tilemann, Lisa ; Schermer, Tjard ; Gindner, Lena ; Laux, Gunter ; Szecsenyi, Joachim ; Meyer, Franz Joachim underlies the terms of Creative Commons Attribution 3.0 Germany

Citation of documents: Please do not cite the URL that is displayed in your browser location input, instead use the DOI, URN or the persistent URL below, as we can guarantee their long-time accessibility.

Abstract

Background: To evaluate the sensitivity, specificity and predictive values of fractional exhaled nitric oxide (FENO) for the diagnosis of asthma in general practice. Methods: Prospective diagnostic study with 160 patients attending 10 general practices for the first time with complaints suspicious of obstructive airway disease (OAD). Patients were referred to a lung function laboratory for diagnostic investigation. The index test was FENO measured with a portable FENO analyser based on electrochemical sensor. The reference standard was the Tiffeneau ratio (FEV1/VC) as received by spirometric manoeuvre and/or results of bronchial provocation. Bronchial provocation with methacholine was performed to determine bronchial hyper-responsiveness (BHR) in the event of inconclusive spirometric results. Results: 88 (55%) were female; their average age was 43.9 years. 75 (46.9%) patients had asthma, 25 (15.6%) had COPD, 8 (5.0%) had an overlap of COPD and asthma, and 52 (32.5%) had no OAD. At a cut-off level of 46 parts per billion (ppb) (n = 30; 18.8%), sensitivity was 32% (95%CI 23–43%), specificity 93% (95%CI 85–97%), positive predictive value (PPV) 80% (95%CI 63–91%), negative predictive value (NPV) 61% (95%CI 52–69%) when compared with a 20% fall in FEV1 from the baseline value (PC20) after inhaling methacholine concentration ≤ 16 mg/ml. At 76 ppb (n = 11; 6.9%) specificity was 100% (95%CI 96–100%) and PPV was 100% (95%CI 72–100). At a cut-off level of 12 ppb (n = 34; 21.3%), sensitivity was 90% (95%CI 79–95%), specificity 25% (95%CI 17–34%), PPV 40% (95%CI 32–50), NPV 81% (95%CI 64–91%) when compared with a 20% fall of FEV1 after inhaling methacholine concentration ≤ 4 mg/ml. Three patients with unsuspicious spirometric results have to be tested with FENO to save one bronchial provocation test. Conclusion: Asthma could be ruled in with FENO > 46 ppb. Mild and moderate to severe asthma could be ruled out with FENO ≤ 12 ppb. FENO measurement with an electrochemical sensor might be reasonable with respect to the time consuming procedure of bronchial provocation, which carries also some risk of severe bronchospasm. Further research is necessary to evaluate the effectiveness of this dual diagnostic strategy. The number needed to diagnose might be improved when the diagnostic precision could be enhanced by future technical developments.

Document type: Article
Journal or Publication Title: Respiratory Research
Volume: 10
Number: 15
Publisher: BioMed Central
Place of Publication: London
Date Deposited: 22 Feb 2016 14:21
Date: 2009
ISSN: 1465-993X
Page Range: pp. 1-11
Faculties / Institutes: Medizinische Fakultät Heidelberg > Medizinische Universitäts-Klinik und Poliklinik
DDC-classification: 610 Medical sciences Medicine
About | FAQ | Contact | Imprint |
OA-LogoDINI certificate 2013Logo der Open-Archives-Initiative