Mechanisms of error detection : Relation between behavioral measures and electrophysiological correlates
Dateien
Datum
Autor:innen
Herausgeber:innen
ISSN der Zeitschrift
Electronic ISSN
ISBN
Bibliografische Daten
Verlag
Schriftenreihe
Auflagebezeichnung
URI (zitierfähiger Link)
Internationale Patentnummer
Link zur Lizenz
Angaben zur Forschungsförderung
Projekt
Open Access-Veröffentlichung
Sammlungen
Core Facility der Universität Konstanz
Titel in einer weiteren Sprache
Publikationstyp
Publikationsstatus
Erschienen in
Zusammenfassung
Detection of behavioral errors and initiation of behavioral adjustments to reduce or compensate negative consequences of errors contribute to an efficient task performance. The present work combines several studies, which investigated mechanisms of error detection by means of behavioral measures and electrophysiological correlates. Study [1] showed that error signaling and error correction depended strongly on the participants' response criterion. This supports the idea that error detection is enabled by internal error corrections. Study [2] showed that the size of the error negativity/error-related negativity (Ne/ERN) is not related to error detectability. This is incompatible with the assumption that the Ne/ERN reflects the information necessary for error detection. Study [3] demonstrated that error detectability, the Ne/ERN, and behavioral adjustments following errors are impaired with increased response set size. Taken together, the results are compatible with the idea that errors are detected by response monitoring and that the Ne/ERN reflects the significance of errors for behavioral adjustments.
Zusammenfassung in einer weiteren Sprache
Die Erkennung von Fehlern im Verhalten und die Initiierung von Verhaltensweisen, die negative Konsequenzen von Fehlern reduzieren und/oder kompensieren, tragen zu einer effizienten Leistung beim Bearbeiten von Aufgaben bei. Die vorliegende Arbeit fasst mehrere Studien zusammen, die Mechanismen der Fehlerdetektion anhand von Verhaltensmaßen und elektrophysiologischen Korrelaten untersuchten. In Studie [1] hingen Fehlersignalisierung und Fehlerkorrektur deutlich vom Antwortkriterium der Versuchsteilnehmer ab. Dies stützt die Annahme, dass Fehlerdetektion durch interne Fehlerkorrektur ermöglicht wird. In Studie [2] hing die Error Negativity/Error-Related Negativity (Ne/ERN) nicht mit der Detektierbarkeit von Fehlern zusammen. Dies widerspricht der Annahme, dass die Ne/ERN auf derselben Information beruht wie die Fehlerdetektion. In Studie [3] waren Fehlerdetektierbarkeit, Ne/ERN und strategische Verhaltensanpassung nach Fehlern bei größeren Antwortsets beeinträchtigt. Zusammengenommen sprechen die Ergebnisse der Studien dafür, dass Fehler durch Antwortüberwachung detektiert werden und dass die Ne/ERN die Wichtigkeit von Fehlern für die Verhaltensanpassung signalisiert.
Fachgebiet (DDC)
Schlagwörter
Konferenz
Rezension
Zitieren
ISO 690
MAIER, Martin E., 2009. Mechanisms of error detection : Relation between behavioral measures and electrophysiological correlates [Dissertation]. Konstanz: University of KonstanzBibTex
@phdthesis{Maier2009Mecha-10393, year={2009}, title={Mechanisms of error detection : Relation between behavioral measures and electrophysiological correlates}, author={Maier, Martin E.}, address={Konstanz}, school={Universität Konstanz} }
RDF
<rdf:RDF xmlns:dcterms="http://purl.org/dc/terms/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:bibo="http://purl.org/ontology/bibo/" xmlns:dspace="http://digital-repositories.org/ontologies/dspace/0.1.0#" xmlns:foaf="http://xmlns.com/foaf/0.1/" xmlns:void="http://rdfs.org/ns/void#" xmlns:xsd="http://www.w3.org/2001/XMLSchema#" > <rdf:Description rdf:about="https://kops.uni-konstanz.de/server/rdf/resource/123456789/10393"> <void:sparqlEndpoint rdf:resource="http://localhost/fuseki/dspace/sparql"/> <bibo:uri rdf:resource="http://kops.uni-konstanz.de/handle/123456789/10393"/> <dc:contributor>Maier, Martin E.</dc:contributor> <dcterms:available rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2011-03-25T09:16:36Z</dcterms:available> <dc:date rdf:datatype="http://www.w3.org/2001/XMLSchema#dateTime">2011-03-25T09:16:36Z</dc:date> <dc:language>eng</dc:language> <dcterms:abstract xml:lang="eng">Detection of behavioral errors and initiation of behavioral adjustments to reduce or compensate negative consequences of errors contribute to an efficient task performance. The present work combines several studies, which investigated mechanisms of error detection by means of behavioral measures and electrophysiological correlates. Study [1] showed that error signaling and error correction depended strongly on the participants' response criterion. This supports the idea that error detection is enabled by internal error corrections. Study [2] showed that the size of the error negativity/error-related negativity (Ne/ERN) is not related to error detectability. This is incompatible with the assumption that the Ne/ERN reflects the information necessary for error detection. Study [3] demonstrated that error detectability, the Ne/ERN, and behavioral adjustments following errors are impaired with increased response set size. Taken together, the results are compatible with the idea that errors are detected by response monitoring and that the Ne/ERN reflects the significance of errors for behavioral adjustments.</dcterms:abstract> <dcterms:title>Mechanisms of error detection : Relation between behavioral measures and electrophysiological correlates</dcterms:title> <dcterms:rights rdf:resource="https://rightsstatements.org/page/InC/1.0/"/> <dspace:hasBitstream rdf:resource="https://kops.uni-konstanz.de/bitstream/123456789/10393/1/Diss_Maier.pdf"/> <dcterms:isPartOf rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/43"/> <dc:format>application/pdf</dc:format> <foaf:homepage rdf:resource="http://localhost:8080/"/> <dcterms:issued>2009</dcterms:issued> <dspace:isPartOfCollection rdf:resource="https://kops.uni-konstanz.de/server/rdf/resource/123456789/43"/> <dcterms:hasPart rdf:resource="https://kops.uni-konstanz.de/bitstream/123456789/10393/1/Diss_Maier.pdf"/> <dc:creator>Maier, Martin E.</dc:creator> <dc:rights>terms-of-use</dc:rights> <dcterms:alternative>Mechanismen der Fehlerdetektion: Zusammenhang zwischen Verhaltensmaßen und elektrophysiologischen Korrelaten</dcterms:alternative> </rdf:Description> </rdf:RDF>