- This paper deals with CUSUM tests for monitoring of intensity parameter of a Poisson process if this process can be observed in a restricted manner only at pregiven equidistant time points. In this case the process can be monitored by means of a CUSUM test for the parameter of a corresponding Poisson distribution. For rational reference parameter values the computation of average run length is reduced to that of solving of a system of simultaneous linear equations. The performance of obtained CUSUM tests is discussed by means of corresponding examples.